These instructions are for a new MINIX PC or one being re-imaged.
- Setup the device
- Connect the device to:
- Keyboard
- Power
- Ethernet
- Monitor via HDMI
- Connect the device to:
- Create bootable media to install OS
- Copy the ISO file from storage1 to your computer (not the MINIX)
- storage1.biola.edu/software/Biola Software/....Software/Digital Signage\digital_signage-18.04.iso
- Get a USB key that's at least 4GB and connect to the same computer
- Open Rufus and use that to create a bootable USB drive from the ISO
- Device - the USB drive
- Boot Selection - the ISO file
- Partition scheme - MBR
- Target system - BIOS or UEFI
- Volume Label - leave default
- File system - FAT32
- Cluster size - leave default
- Take the USB key and connect it to the MINIX
- Copy the ISO file from storage1 to your computer (not the MINIX)
- Set BIOS settings
- Boot the device and press F11 to enter boot menu.
- Select system setup and set the following:
- BIOS password (lastpass)
- auto-on time
- power recovery
- Save and Exit with Restart
- Image the MINIX
- Boot the device and press F11 to enter boot menu.
- Select the USB key you created and press enter
- After it boots, it will show a screen with options
- Select "Install" and press Enter
- It will go through all the steps from there
- It will shutdown when its done
- Gather Information
- Get the MAC address of the device - on a sticker on the bottom of the MINIX
- Have Network Services create a DNS reservation for the sign using the MAC address
- Similar to how we do printers
- in the .signage.biola.edu domain
- The DNS name will match the location of the sign, i.e. sigmachi.signage.biola.edu
- Get the IP address they assign the DNS address
- Send the information in a ticket to the System Administrators
- Schedule a time with them to deploy the hardware.
- Deploy Hardware
- Deploy the Minix to the location, connecting power and HDMI to the digital sign.
- Power on the Minix, it should boot to the Ubuntu login screen.
- Inform the sysadmin that the hardware is in place.
- The sysadmin will deploy the configuration to the Minix remotely, which takes about 5 minutes.
- Verify that the sign is working.